• Probe Types

    Keysight offers a broad range of voltage, current, and optical probing solutions for InfiniiVision and Infiniium Series oscilloscopes. Select from the probe categories listed below to see what Keysight has to offer.

    Hi-Z+ PASSIVE PROBING SYSTEM

    Keysight offers a family of single-ended passive probes offers the performance expected of an active probe with the usability expected from a passive probe. The Hi-Z+ probes support higher input voltages and support for simplified probing of MMCX connectors. All three of these probes leverage the PP0004A Hi-Z+ Adapter to interface with our current generation oscilloscopes with AutoProbe 1 interfaces. There are also a variety of accessory kits available for extra parts or replacements.

    PP000xA Hi-Z+ Probes
    Model Bandwidth Input Voltage Input Impedance Tip Type
    PP0001A 1 GHz
    300 V CAT II 10 M? // 4.0 pF
    5mm tip
    PP0002A 800 MHz 1200 V CAT II
    40 M? // 2.0 pF 5mm tip
    PP0003A 1 GHz
    30 V CAT II
    10 M? // 4.0 pF
    MMCX Connector

    ?

    Passive Probes

    Keysight offers a broad range of passive probes with various attenuation ratios and input impedance specifications to optimize the dynamic range and loading considerations of your oscilloscope ground-reference measurements. These passive probes are compatible with most Keysight oscilloscopes that have either standard BNC inputs or AutoProbe1/BNC input connections.

    General-Purpose Passive Probes
    Model Bandwidth Attenuation Ratio Input Impedance1 Compensation Range2
    Notes
    N2840A 50 MHz
    10:1 10 M? // 11 pF
    5 - 30 pF
    ?
    10074D 150 MHz 10:1 10 M? // 15 pF
    9 - 17 pF
    ?
    N2841A 150 MHz
    10:1 10 M? // 11 pF
    5 - 30 pF
    Recommended for InfiniiVision 2000 X-Series
    N2871A 200 MHz 10:1 10 M? // 9.5 pF
    10 - 25 pF
    Optimized for fine-pitch probing
    N2842A
    300 MHz
    10:1
    10 M? // 11 pF
    5 - 30 pF
    Recommended for InfiniiVision 2000 X-Series
    N2853A
    350 MHz
    10:1
    10 M? // 11 pF
    5 - 30 pF
    ?
    N2872A
    350 MHz
    10:1 10 M? // 9.5 pF
    10 -25 pF
    Optimized for fine-pitch probing
    N7007A
    400 MHz 10:1 10 M? // 16 pF
    6 - 18 pF
    Extreme temperature probing? (-40 to +85°C), 2 meter cable
    N2843A 500 MHz
    10:1 10 M? // 11 pF
    5 - 30 pF
    Recommended for InfiniiVision 3000 X-Series
    10073D
    500 MHz
    10:1 2.2 M? // 12 pF
    6 - 15 pF
    ?
    ?N2873A ? 500 MHz 10:1 10 M? // 9.5 pF 10-25 pF Fine-pitch, recommended for Infiniium EXR/MXR/S-Series
    ?N2875A ? 500 MHz 20:1 20 M? // 5.6 pF 7 - 20 pF Optimized for fine-pitch, low-capacitive probing
    N2894A ? 700 MHz 10:1 10 M? // 9.5 pF 10 - 25 pF Fine-pitch, recommended for InfiniiVision 4000/6000 X-Series
    PP0002A 800 MHz variable 40 M? // 2.0 pF N/A 5 mm tip, 1200 V CAT II, requires PP0004A (AutoProbe 1)?
    PP0001A 1 GHz variable 10 M? // 4.0 pF N/A 5 mm tip, 300 V CAT II,?requires PP0004A (AutoProbe 1)?
    PP0003A 1 GHz variable 10 M? // 4.0 pF N/A MMCX connector, 30 V CAT II, requires PP0004A (AutoProbe 1)?
    High-Sensitivity 1:1 Passive Probes
    Model Bandwidth Attenuation Ratio Input Impedance1,3 Compensation Range
    Notes
    10070D 20 MHz 1:1 1 M? // 70 pF +? N/A

    Recommended for low-voltage measurements? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??

    N2870A ?35 MHz? 1:1 1 M? // 39 pF +? N/A Recommended for low-voltage measurements? ? ? ? ? ??
    Switchable Passive Probes (1:1 // 10:1)
    Model Bandwidth Attenuation Ratio Input Impedance1,3 Compensation Range2
    Notes
    ? ?N2142A? ? 6 MHz 1:1 1 M? // 100 pF +? N/A

    Low-cost 2-pack, recommended for InfiniiVision EDUX1000 X-Series

    70 MHz 10:1 10 M? // 15 pF + 15 - 30 pF
    ? ?N2140A? ? 6 MHz 1:1 1 M? // 100 pF +

    N/A

    Low-cost 2-pack, recommended for InfiniiVision EDUX1000 X-Series

    200 MHz 10:1 10 M? // 15 pF +
    15 - 30 pF
    ? ?N2889A? ? 10 MHz 1:1 1 M? // 60 pF + N/A The most general-purpose passive probe
    350 MHz 10:1 10 M? // 11 pF + 10 - 35 pF
    High-voltage Passive Probe (100:1)
    Model Bandwidth Atten. Ratio Input Impedance1 Compensation Range2
    Notes
    10076C ? ? 500 MHz? ?? ? 100:1 ? ?66.7 M? // 3 pF +? ? 6 - 18 pF? ?

    High-voltage, low capacitive probing

    High-frequency/Low-Z Passive Probes (50-? terminated)
    Model Bandwidth Attenuation Ratio Input Impedance4 Compensation Range
    Notes
    N2874A
    1.5 GHz 10:1
    500 ? // 1.8 pF + N/A

    Low-cost, high-frequency probing at the cost of resistive loading

    N2876A 1.5 GHz 100:1 5 k? // 2.2 pF +? N/A Low-cost, high-frequency probing at the cost of resistive loading
    TDR/TDT Probe
    Model Bandwidth Type Input Impedance Tip Spacing Compatible TDR/TDT Modules Notes
    N1021B 18 GHz Differential 100??? variable between 0.5mm-2.54mm

    DCA-X N1055A & 54754A

    Designed for TDR applications, but also suitable as high bandwidth, passive probe for non-TDR applications
    Passive Probes for Handheld Digital Oscilloscopes
    Model Bandwidth Attenuation Ratio Input Capacitance Length Safety Rating
    U1560A 45 MHz
    1:1 42 pF
    1.2 m Cat III 300 V
    U1561A 250 MHz 10:1 16 pF
    1.2 m
    Cat III 600 V, Cat II 1000 V
    U1562A 300 MHz
    100:1 6.5 pF
    1.2 m Cat III 600 V, Cat II 1000 V, Cat I 3540 V

    1. Input impedance when terminated into oscilloscopes with 1-M? input terminations. For higher-bandwidth Infiniium oscilloscopes with 50-? input terminations only, the E2697A high impedance adapter can be purchased (includes 10073D 500-MHz passive probe) to provide a 1-M? input termination.?

    2. For proper probe compensation (flatness), the oscilloscope’s input capacitance must be within the specified compensation range of the probe.?

    3. Capacitance at the probe tip of 1:1 probes is the specified probe capacitance plus the capacitance of the oscilloscope when terminated into 1-M?.

    4. Input impedance when terminated into oscilloscopes with 50-? input terminations. These probes are not compatible with Keysight’s InfiniiVision 1000 and 2000 X-Series oscilloscopes.?

    High-Frequency Differential Active Probes <?10?GHz

    Probing high-speed differential buses typically requires differential active probes. Keysight offers a broad range of differential active probing solutions for your unique measurement requirements based on bandwidth, dynamic measurement range, and probe loading.

    High-Frequency Differential Active Probes? < 10 GHz
    Model Bandwidth Input Range Probe Offset Diff Input Impedance Attenuation Ratio Prob-to-scope Interface Power Source Oscilloscope Termination
    N2792A 200 MHz ±20 V N/A 1 M?/3.5 pF 10:1 BNC USB cable or battery? 50 ?
    N2818A 200 MHz ±20 V N/A 1 M?/3.5 pF 10:1 AutoProbe1 Oscilloscope 50 ?
    N2793A 800 MHz ±15 V N/A 200 k?/1.0 pF 10:1 BNC USB cable or battery 50 ?
    N2819A 800 MHz ±15 V N/A 200 k?/1.0 pF 10:1 AutoProbe1 Oscilloscope 50 ?
    N2750A 1.5 GHz ±5 V ±15 V 100 k?/0.7 pF 2:1/10:11 AutoProbe1 Oscilloscope 50 ?
    N2751A 3.5 GHz ±5 V
    ±15 V 100 k?/0.7 pF 2:1/10:11 AutoProbe1 Oscilloscope 50 ?
    N2752A 6.0 GHz ±5 V ±15 V 100 k?/0.7 pF 2:1/10:11 AutoProbe1 Oscilloscope 50 ?
    1130B2 1.5 GHz ±2.5 V ±12 V 50 k?/0.27 pF 10:1 AutoProbe1 Oscilloscope 50 ?
    1131B2
    3.5 GHz ±2.5 V ±12 V 50 k?/0.27 pF 10:1 AutoProbe1 Oscilloscope 50 ?
    1132B2 6.0 GHz ±2.5 V ±12 V 50 k?/0.27 pF 10:1 AutoProbe1 Oscilloscope 50 ?
    1134B2 7.0 GHz ±2.5 V ±12 V 50 k?/0.27 pF 10:1 AutoProbe1 Oscilloscope 50 ?
    N2830A2,3 4 GHz ±2.5 V ±16 V 100 k?/0.32 pF 5:1/10:11 AutoProbe1 Oscilloscope 50 ?
    N2831A2,3 8 GHz ±2.5 V ±16 V 100 k?/0.32 pF
    5:1/10:11 AutoProbe1 Oscilloscope 50 ?
    N7000A2 8 GHz ±2.5 V ±16 V 100 k?/0.32 pF 5:1/10:11 AutoProbe2 Oscilloscope 50 ?
    1. Auto-selected based on V/division setting.
    2. Requires differential probe head sold separately.
    3. Not compatible with InfiniiVision X-Series oscilloscopes, but is compatible with the Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A and N2852A adapters
    Oscilloscope Compatibility for High-Frequency Differential Active Probes (<10 GHz)
    Probe-to-scope Interface
    Scope Termination
    Compatible Oscilloscopes
    BNC 50 ?
    • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series?
    • Infiniium EXR, MXR, S-Series, 9000 Series
    • Any vendor’s oscilloscope with a BNC input connection and a 50 ? input impedance termination?
    AutoProbe1

    50 ?

    • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series (except N2830A and N2831A)
    • Infiniium EXR, MXR, S-Series, 9000, and 90000A Series
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter
    AutoProbe2 50 ?
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series

    AutoProbe Interface

    Keysight’s AutoProbe interface provides the following:

    • DC voltage to power active probe circuitry
    • Automatic detection of probe attenuation
    • Automatic control of selectable probe attenuation on some probes
    • Probe DC offset on many probes

    High-Frequency Differential Active Probes ≥?10?GHz

    Get the highest performance available for measuring differential and single-ended signals on high-density integrated circuits and printed circuit boards.? ?

    As devices get smaller and faster, accurately probing signals becomes more challenging. Keysight’s InfiniiMax Probing System has the most accurate probe amplifiers, the widest variety of probe heads, and all the accessories you need to get the job done.

    High-Frequency Differential Active Probes?≥?10 GHz
    Model Bandwidth Impedance Profile1 Diff Input Impedance Probe Noise2 Probe-to-Scope Interface InfiniiMode3 Input Range Probe Offset Attenuation Range4
    N2803A 30 GHz RCRC 100 k??/0.32 pF
    23.9 nV/rt(Hz) AutoProbe2 No ±1.25 V
    ±16 V
    6:1
    MX0025A 25 GHz RC 50 k?/0.17 pF 25.0 nV/rt(Hz) AutoProbe2 Yes ±2.5 V ±16 V 1:1/4:1/8:1
    MX0023A 25 GHz RC 50 k?/0.17 pF 25.0 nV/rt(Hz) AutoProbe2
    No ±1.25 V ±16 V 1:1/4:1
    N2802A 25 GHz RCRC 100 k??/0.32 pF 23.9 nV/rt(Hz) AutoProbe2
    No ±1.25 V ±16 V 6:1
    MX0024A 20 GHz RC 50 k?/0.17 pF 25.0 nV/rt(Hz) AutoProbe2 Yes ±2.5 V ±16 V 1:1/4:1/8:1
    N2801A 20 GHz RCRC 100 k??/0.32 pF 23.9 nV/rt(Hz) AutoProbe2
    No ±1.25 V ±16 V 6:1
    N7003A 20 GHz RCRC 100 k??/0.32 pF 33.5 nV/rt(Hz) AutoProbe2
    Yes ±2.5 V ±16 V 5:1/10:1
    MX0022A 16 GHz RC 50 k?/0.17 pF 25.0 nV/rt(Hz) AutoProbe2 Yes ±2.5 V ±16 V 1:1/4:1/8:1
    N7002A 16 GHz RCRC 100 k??/0.32 pF 33.5 nV/rt(Hz) AutoProbe2
    Yes ±2.5 V ±16 V 5:1/10:1
    MX0021A 13 GHz RC 50 k?/0.17 pF 25.0 nV/rt(Hz) AutoProbe2 Yes ±2.5 V ±16 V 1:1/4:1/8:1
    N7001A 13 GHz RCRC 100 k??/0.32 pF 33.5 nV/rt(Hz) AutoProbe2
    Yes ±2.5 V ±16 V 5:1/10:1
    N2832A 13 GHz RCRC 100 k??/0.32 pF 33.5 nV/rt(Hz) AutoProbe1
    Yes ±2.5 V ±16 V 5:1/10:1
    1169B 13 GHz RC 50 k??/0.21 pF 25.0 nV/rt(Hz) AutoProbe1
    No ±1.65 V ±16 V 3.45:1
    MX0020A 10 GHz RC 50 k?/0.17 pF 25.0 nV/rt(Hz) AutoProbe2 Yes ±2.5 V ±16 V 1:1/4:1/8:1
    1168B 10 GHz RC 50 k??/0.21 pF 25.0 nV/rt(Hz) AutoProbe1
    No ±1.65 V ±16 V 3.45:1

    1.? Input Impedance Profile: RCRC architecture is the best choice for signals with low source impedance and RC architecture is the best choice for measuring signals that transition to low power modes because it has lower loading.

    2.? Probe noise listed is the most common setup. Probe noise can vary with multiple factors such as attenuation ratio, probe head, and probe mode.

    3.? Measure differential, single-ended, and common mode signals.

    4.? Auto selected based on volts/division (all modes).

    Oscilloscope Compatibility for High-Frequency Differential Active Probes?≥?10 GHz
    Probe-to-scope Interface
    Compatible Oscilloscopes
    AutoProbe1

    Infiniium MXR, EXR, S-Series, 9000, and 90000A Series

    Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter

    Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the?N5442A?&?N2852A?adapters

    AutoProbe2

    Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series

    Infiniium UXR (1 mm & 1.85 mm models) with the use of the N2852A adapter

    Infiniium N1000A and 86100D DCA-X with the use of the N5477A?adapter (only for N2801A/02A/03A)?

    High-Voltage Differential Active Probes

    Keysight offers a broad range of high-voltage differential probes to help test power-related devices and circuits including probes with high input impedance for minimal loading, probes with multiple attenuation ratios for optimum dynamic range measurements, and probes that can measure up to ±7000 Volts.

    High-Voltage Differential Active Probes
    Model Bandwidth Input Range Diff Input Impedance Attenuation Ratio Prob-to-scope Interface Power Source Oscilloscope Termination
    N2793A
    800?MHz ±15 V
    200 k?/1.0 pF
    10:1 AutoProbe1
    Oscilloscope? 50 ?
    N2819A
    800?MHz ±15 V
    200 k?/1.0 pF
    10:1 AutoProbe1 Oscilloscope 50 ?
    N2792A
    200 MHz ±20 V
    1 M?/3.5 pF
    10:1 BNC USB cable or battery 50 ?
    N2818A
    200 MHz ±20 V
    1 M?/3.5 pF
    10:1 AutoProbe1 Oscilloscope 50 ?
    N2805A
    200 MHz
    ±100 V 4 M?/4.0 pF
    50:1 AutoProbe1 Oscilloscope 50 ?
    N2804A
    300 MHz
    ±300 V
    8 M?/10 pF
    100:1
    AutoProbe1 Oscilloscope 50 ?
    N2791A
    25 MHz
    ±700 V
    8 M?/3.5 pF
    10:1/100:1 BNC
    USB cable or battery
    1 M?
    N2790A
    100 MHz
    ±1400 V
    1 M?/3.5 pF
    50:1/500:1
    AutoProbe1 Oscilloscope 1 M?
    DP0001A
    400 MHz
    ±2000 V
    10 M?/2.0 pF
    50:1/100:1/250:1/500:1
    AutoProbe1 Oscilloscope 50 ?
    N2891A
    70 MHz
    ±7000 V
    100 M?/5.0 pF
    100:1/1000:1
    BNC
    USB cable or battery
    1 M?
    Oscilloscope Compatibility for High-Voltage Differential Active Probes
    Probe-to-scope Interface
    Oscilloscope Termination
    Compatible Oscilloscopes
    BNC 1 M?
    • InfiniiVision 1000, 2000, 3000A, 3000T, 4000, and 6000 X-Series
    • Infiniium EXR, MXR, S-Series, 9000 Series
    • Any vendor’s oscilloscope with a BNC input connection and a?1 M??input impedance termination?
    BNC

    50 ?

    • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series
    • Infiniium EXR, MXR, S-Series, 9000 and 90000A Series
    • Any vendor’s oscilloscope with a BNC input connection and a 50 ? input impedance termination
    AutoProbe11 50 ?
    • InfiniiVision 3000A1, 3000T, 4000, and 6000 X-Series
    • Infiniium?EXR, MXR, S-Series, 9000 and 90000A Series
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter
    • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A & N2852A adapters


    1.? DP0001A is not compatible with the InfiniiVision 3000A X-Series oscilloscopes.

    AutoProbe1 Interface

    Keysight’s AutoProbe1 interface provides the following:

    • DC voltage to power active probe circuitry
    • Automatic detection of probe attenuation
    • Automatic control of selectable probe attenuation on some probes
    • Probe DC offset on many probes

    Single-Ended Active Probes

    Measurements Referenced to Ground

    When capacitive loading and limited bandwidth of conventional passive probes begin to degrade the measurement integrity of your high-speed signals, consider using one of Keysight’s higher bandwidth single-ended active probes.

    Single-Ended Active Probes
    Model Bandwidth Input Range Probe Offset Input Impedance Attenuation Ratio Probe-to-scope Interface Notes
    N2795A 1 GHz ±8 V
    ±8 V 1 M?/1.0 pF
    10:1 AutoProbe1
    ?
    N2797A ?1.5 GHz ±8 V
    ±12 V 1 M?/1.0 pF
    10:1 AutoProbe1

    Extreme Temp. (-40 to +85° C),?2 meter long cable

    N2796A 2 GHz
    ±8 V
    ±12 V 1 M?/1.0 pF
    10:1 AutoProbe1
    ?
    1130B1 1.5 GHz ±2.5 V ±12 V 25 k?/0.44 pF
    10:1 AutoProbe1 ?
    1131B1 3.5 GHz
    ±2.5 V
    ±12 V 25 k?/0.44 pF
    10:1
    AutoProbe1 ?
    1132B1 5.0 GHz
    ±2.5 V
    ±12 V 25 k?/0.44 pF
    10:1
    AutoProbe1 ?
    1134B1 7.0 GHz
    ±2.5 V
    ±12 V 25 k?/0.44 pF
    10:1
    AutoProbe1
    ?
    1. Single-ended and differential probe. Requires probe head sold separately.
    Oscilloscope Compatibility for Single-Ended Active Probes
    Probe-to-scope Interface
    Compatible Oscilloscopes
    AutoProbe1
    • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series
    • Infiniium EXR, MXR, S-Series, 9000, and 90000A Series
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the N5442A?adapter
    • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A & N2852A adapters (only for N2795A/96A/97A, not for 1130B/31B/32B/34B)?

    AutoProbe1 Interface

    Keysight’s AutoProbe1 interface provides the following:

    • DC voltage to power active probe circuitry
    • Automatic detection of probe attenuation
    • Automatic control of selectable probe attenuation on some probes
    • Probe DC offset on many probes

    Power Rail Probes

    Measure Output Ripple with High-Sensitivity

    Engineers often use 1:1 passive probes for the sensitivity required to measure the output ripple of DC supplies. But 1:1 passive probes have limited bandwidth (typically less than 35 MHz) and no DC offset capability. A Keysight power rail probe can measure noise, output ripple, and transients on DC power supplies with high sensitivity (millivolts), large DC offsets, and high bandwidth.

    Power Rail Probes
    Model Bandwidth Input Range Probe Offset Input Impedance Attenuation Ratio Probe-to-scope Interface
    N7020A 2 GHz ±850 mV1 ±24 V
    50 k? 1.1:1 AutoProbe1
    N7024A 6 GHz ±600 mV1 ±15 V
    50 k?
    1.3:1 AutoProbe1
    1. Measurement range about offset level.?
    Oscilloscope Compatibility for Power Rail Probes
    Model? Compatible Oscilloscopes
    N7020A
    • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series oscilloscopes.
    • Infiniium EXR, MXR, S-Series, and 9000, and 90000A Series oscilloscopes.
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter.
    N7024A
    • Infiniium EXR, MXR, S-Series, and 9000, and 90000A Series oscilloscopes.
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter.

    AutoProbe1 Interface

    Keysight’s AutoProbe1 interface provides the following:

    • DC voltage to power active probe circuitry
    • Automatic detection of probe attenuation
    • Automatic control of selectable probe attenuation on some probes
    • Probe DC offset on many probes

    Current Probes

    Keysight offers a broad range of current probing solutions including clamp-on current probes with bandwidths from DC to 150 MHz, Rogowski coils that can measure peak currents up to 3000 Amps, and high-sensitivity R-shunt probes that can measure current as low as 50 μA.

    AC/DC Hall-Effect (Clamp-On) Current Probes
    Model Bandwidth Max Current Conversion Factor (Attenuation) Min Scope Vertical Scale? Probe-to-Scope Interface Power Source
    N7026A 150 MHz 40 A-Pk1, 30 A-RMS1
    1 V/A (1:1), 0.2 V/A (5:1)2
    1 mA/div AutoProbe1 Oscilloscope
    N2893A 100 MHz 30 A-Pk3, 24 A-RMS3 0.1 V/A (10:1) 10 mA/div AutoProbe1 Oscilloscope
    N2783B 100 MHz 50 A-Pk, 30 A-RMS 0.1 V/A (10:1) 10 mA/div BNC N2779A
    1147B 50 MHz 30 A-Pk3, 24 A-RMS3
    0.1 V/A (10:1) 10 mA/div AutoProbe1 Oscilloscope
    N2782B 50 MHz 50 A-Pk, 30 A-RMS 0.1 V/A (10:1) 10 mA/div BNC N2779A
    N2781B 10 MHz 300 A-Pk, 150 A-RMS 0.01 V/A (100:1)? 100 mA/div BNC N2779A
    N2780B 2 MHz 700 A-Pk, 500 A-RMS 0.01 V/A (100:1)? 100 mA/div BNC N2779A
    1146B 100 kHz 100 A-Pk, 100 A-RMS 0.1 V/A (10:1), 0.01 V/A (100:1)4
    10 mA/div BNC 9 V Battery
    AC-Only Rogowski Current Probes
    Model Bandwidth Max Current Conversion Factor (Attenuation) Probe-to-Scope Interface Power Source
    N7042A 9.2 Hz- 30 MHz 300 A-Pk 0.02 V/A (50:1) BNC AC power adapter or 4x AA batteries
    N7041A 12 Hz - 30 MHz 600 A-Pk 0.01 V/A (100:1) BNC AC power adapter or 4x AA batteries
    N7040A 3 Hz - 23 MHz 3000 A-Pk 0.002 V/A (500:1) BNC AC power adapter or 4x AA batteries
    High-Sensitivity AC/DC R-Shunt Current Probes
    Model Bandwidth Current Range5 Gain Channels Probe Heads (Standard) Probe-to-Scope Interface Power Source
    N2820A

    Zoom-out: 3 MHz

    Zoom-in: 500 kHz

    Zoom-out: 5 A

    Zoom-in: 50 μ A?

    Zoom-out: 1.97

    Zoom-in: 300
    2

    20 m?, 100 m?,

    User-defined
    AutoProbe1 Oscilloscope
    N2821A

    Zoom-out: 3 MHz

    Zoom-in: 500 kHz

    Zoom-out: 5 A

    Zoom-in: 50 μ A?

    Zoom-out: 1.97

    Zoom-in: 300

    1

    20 m?, 100 m?,

    User-defined
    AutoProbe1 Oscilloscope
    1. When using a power adapter booster (standard). 15 A-Pk, 5 V-RMS without oscilloscope-provided power only. An MXR/EXR enables max current range without using the power adapter.
    2. Auto-selected based on Amps/division setting.
    3. The maximum number of current probes supported by InfiniiVision oscilloscopes is limited depending on the oscilloscope. Infiniium oscilloscopes have no limitations.
    4. Manually selectable.?
    5. A wider input range is possible when using the user-defined head and Rsense.
    Oscilloscope Compatibility for Current Probes
    Probe-to-scope Interface
    Compatible Oscilloscopes
    BNC
    • InfiniiVision 1000, 2000, 3000A, 3000T, 4000, and 6000 X-Series
    • Infiniium EXR, MXR, S-Series, 9000, and 90000A Series
    • Any vendor’s oscilloscope with a BNC input connection and a 1 M? input?impedance termination
    AutoProbe1
    • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series
    • Infiniium EXR, MXR, S-Series, and 9000 and 90000A Series
    • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter
    • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the?N5442A?& N2852A adapters (only for 1147B and N2893A, not for N7026A, N2820A/21A)

    AutoProbe1 Interface

    Keysight’s AutoProbe1 interface provides the following:

    • DC voltage to power active probe circuitry
    • Automatic detection of probe attenuation
    • Automatic control of selectable probe attenuation on some probes
    • Probe DC offset on many probes

    Optical Probes

    Keysight offers fully-integrated optical front-end solutions for Infiniium real-time oscilloscopes. The solution is designed for reference receiver testing of industry optical standards or characterizing the raw response of an optical transmitter. It can also be used to view optical streams at speeds up to 56 Gbaud PAM4, making it an ideal solution for characterizing or troubleshooting high-speed optical signals in system level testing and debugging.

    Optical Probes
    Model Bandwidth Inputs Input Connector Type Wavelength Range Required Infiniium Baseline Software Output Connector Type Compatible Oscilloscopes
    N7004A 33 GHz Single-mode & Multi-mode FC/PC to 50/125 um fiber? 750 nm to 1650 nm Version 05.70 or higher 2.92 mm female UXR (3.5 mm models), V, Z, Q, and 90000X
    N7005A 60 GHz Single-mode FC/PC to 9/125 um fiber? 1250 nm to 1600 nm Version 10.25 or higher 1.85 male UXR (1 mm & 1.85 mm models)